The SRP-10 is a high-accuracy RTD data logger designed for demanding applications from cryogenic storage to high-heat processes. It accepts 2-, 3-, and 4-wire RTDs (best accuracy with 4-wire) and combines three external channels with an internal ambient channel for wide-ranging monitoring.

Key Features

  • Four channels – 3 external RTD channels + 1 internal thermistor for ambient temperature
  • Supports 2-, 3-, and 4-wire RTDs (highest accuracy with 4-wire)
  • Wide measurement range: -230°C to +300°C (-382°F to +572°F)
  • High accuracy: ±0.3°C (±0.54°F) + resolution or ±0.06% full scale
  • Memory capacity: 128 KB (up to 87,000 readings)
  • User-selectable sampling: from 25 per second to once every 8 hours
  • Battery powered with long-life 3.6V lithium cell (external power options available)
  • Networking: link up to 10 SmartReader Plus loggers together
SKU: 01-0132
$1,262.00 USD

Guaranteed safe checkout

american expressdiners clubdiscovermasterpaypalvisa

The SmartReader Plus 10 (SRP-10) is a proven RTD data logger built for research, QA, and temperature-critical industrial applications. With four total channels — three external RTD inputs and one internal thermistor channel — the SRP-10 delivers the accuracy, flexibility, and ruggedness required in industries where reliable temperature monitoring is non-negotiable.

Supported RTD Types

  • 2-wire RTDs: Supported, though lead resistance may introduce error.

  • 3-wire RTDs: Common in industrial use; compensates for lead resistance in balanced wiring.

  • 4-wire RTDs: Recommended for highest accuracy; eliminates lead resistance effects.

Any platinum RTD probe with a Temperature Coefficient of Resistance (TCR) of 0.00385 can be used with the SRP-10.

Specifications

Accuracy * +/- 0.3ºC (+/- 0.54ºF) + resolution
* 100 and 1000 Ohm probes only
No. of Channels Four (one for ambient temperature and three for temperature with RTD probes)
Resolution * +/- 0.14°C (+/- 0.25°F)
* 100 and 1000 Ohm probes only
RTD Type Any 100 or 1000 ohm Platinum RTD with a Temperature Coefficient of Resistance (TCR) of 0.00385
Temperature Range* -230 to 300°C (-382 to 572°F)
* 100 and 1000 Ohm probes only
Warranty 3 – years
Wiring Configurations 2, 3, or 4 wire RTDs

Accessories

Software & Interface Cable are required for full functionality of the product.

Weatherproof Box

Software

ACR software tools are intuitive and flexible, allowing you to easily configure ACR data loggers to collect the data you need. Once downloaded, your data is displayed in presentation-quality graphs and can be converted into popular formats for use with spreadsheet programs, document editors, and other third-party applications.

TrendReader Full License TrendReader Interface Pkg TrendReader on USB Full

Documentation

For a product sheet, please click below for a pdf version.

Product Sheet

A link to the Manual is available by clicking on the link below.

SmartReader Plus Manual

Q&A

Click here to visit our NEW Q&A pages.

Calibration

Data loggers are often used in highly regulated environments such as food and pharmaceutical production and storage where strict safety regulations apply. Regulatory agencies generally require proof of calibration.

ACR calibrations are performed using reference standards that have been calibrated and are traceable to the US National Institute of Standards & Technology (NIST). This ensures that all ACR data loggers meet, and perform to, their published specifications, allowing you to be confident that they will assist you in achieving your compliance requirements.

Calibration certificates are provided with every calibration we perform. ACR Systems is an ISO 9001:2015 registered company and calibration records are kept as part of our quality system and can be made available for customer audits.

Calibration Service

{"id":6149856002219,"title":"SmartReader Plus 10 - Three-Channel RTD Temperature Logger","handle":"smartreader-plus-10","description":"\u003cp data-start=\"1259\" data-end=\"1632\"\u003eThe SmartReader Plus 10 (SRP-10) is a proven RTD data logger built for research, QA, and temperature-critical industrial applications. With four total channels — three external RTD inputs and one internal thermistor channel — the SRP-10 delivers the accuracy, flexibility, and ruggedness required in industries where reliable temperature monitoring is non-negotiable.\u003c\/p\u003e\n\u003ch3 data-start=\"1634\" data-end=\"1660\"\u003eSupported RTD Types\u003c\/h3\u003e\n\u003cul data-start=\"1661\" data-end=\"1930\"\u003e\n\u003cli data-start=\"1661\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1663\" data-end=\"1736\"\u003e\u003cstrong data-start=\"1663\" data-end=\"1679\"\u003e2-wire RTDs:\u003c\/strong\u003e Supported, though lead resistance may introduce error.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1737\" data-end=\"1835\"\u003e\n\u003cp data-start=\"1739\" data-end=\"1835\"\u003e\u003cstrong data-start=\"1739\" data-end=\"1755\"\u003e3-wire RTDs:\u003c\/strong\u003e Common in industrial use; compensates for lead resistance in balanced wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1836\" data-end=\"1930\"\u003e\n\u003cp data-start=\"1838\" data-end=\"1930\"\u003e\u003cstrong data-start=\"1838\" data-end=\"1854\"\u003e4-wire RTDs:\u003c\/strong\u003e Recommended for highest accuracy; eliminates lead resistance effects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1932\" data-end=\"2051\"\u003eAny platinum RTD probe with a Temperature Coefficient of Resistance (TCR) of 0.00385 can be used with the SRP-10.\u003c\/p\u003e","published_at":"2020-12-18T20:42:00-08:00","created_at":"2020-12-18T20:42:00-08:00","vendor":"ACR Systems","type":"","tags":["SmartReader Plus Family"],"price":126200,"price_min":126200,"price_max":126200,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37804123979947,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"01-0132","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SmartReader Plus 10 - Three-Channel RTD Temperature Logger","public_title":null,"options":["Default Title"],"price":126200,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2358_400_300.jpg?v=1610170794","\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2362_400_300.jpg?v=1610170816","\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2365_400_300.jpg?v=1610170839"],"featured_image":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2358_400_300.jpg?v=1610170794","options":["Title"],"media":[{"alt":null,"id":15547901247659,"position":1,"preview_image":{"aspect_ratio":1.267,"height":300,"width":380,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2358_400_300.jpg?v=1610170794"},"aspect_ratio":1.267,"height":300,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2358_400_300.jpg?v=1610170794","width":380},{"alt":null,"id":15547901673643,"position":2,"preview_image":{"aspect_ratio":3.053,"height":131,"width":400,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2362_400_300.jpg?v=1610170816"},"aspect_ratio":3.053,"height":131,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2362_400_300.jpg?v=1610170816","width":400},{"alt":null,"id":15547902623915,"position":3,"preview_image":{"aspect_ratio":1.384,"height":289,"width":400,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2365_400_300.jpg?v=1610170839"},"aspect_ratio":1.384,"height":289,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2365_400_300.jpg?v=1610170839","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp data-start=\"1259\" data-end=\"1632\"\u003eThe SmartReader Plus 10 (SRP-10) is a proven RTD data logger built for research, QA, and temperature-critical industrial applications. With four total channels — three external RTD inputs and one internal thermistor channel — the SRP-10 delivers the accuracy, flexibility, and ruggedness required in industries where reliable temperature monitoring is non-negotiable.\u003c\/p\u003e\n\u003ch3 data-start=\"1634\" data-end=\"1660\"\u003eSupported RTD Types\u003c\/h3\u003e\n\u003cul data-start=\"1661\" data-end=\"1930\"\u003e\n\u003cli data-start=\"1661\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1663\" data-end=\"1736\"\u003e\u003cstrong data-start=\"1663\" data-end=\"1679\"\u003e2-wire RTDs:\u003c\/strong\u003e Supported, though lead resistance may introduce error.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1737\" data-end=\"1835\"\u003e\n\u003cp data-start=\"1739\" data-end=\"1835\"\u003e\u003cstrong data-start=\"1739\" data-end=\"1755\"\u003e3-wire RTDs:\u003c\/strong\u003e Common in industrial use; compensates for lead resistance in balanced wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1836\" data-end=\"1930\"\u003e\n\u003cp data-start=\"1838\" data-end=\"1930\"\u003e\u003cstrong data-start=\"1838\" data-end=\"1854\"\u003e4-wire RTDs:\u003c\/strong\u003e Recommended for highest accuracy; eliminates lead resistance effects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1932\" data-end=\"2051\"\u003eAny platinum RTD probe with a Temperature Coefficient of Resistance (TCR) of 0.00385 can be used with the SRP-10.\u003c\/p\u003e"}
Translation missing: en.general.search.loading
{"id":6149856002219,"title":"SmartReader Plus 10 - Three-Channel RTD Temperature Logger","handle":"smartreader-plus-10","description":"\u003cp data-start=\"1259\" data-end=\"1632\"\u003eThe SmartReader Plus 10 (SRP-10) is a proven RTD data logger built for research, QA, and temperature-critical industrial applications. With four total channels — three external RTD inputs and one internal thermistor channel — the SRP-10 delivers the accuracy, flexibility, and ruggedness required in industries where reliable temperature monitoring is non-negotiable.\u003c\/p\u003e\n\u003ch3 data-start=\"1634\" data-end=\"1660\"\u003eSupported RTD Types\u003c\/h3\u003e\n\u003cul data-start=\"1661\" data-end=\"1930\"\u003e\n\u003cli data-start=\"1661\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1663\" data-end=\"1736\"\u003e\u003cstrong data-start=\"1663\" data-end=\"1679\"\u003e2-wire RTDs:\u003c\/strong\u003e Supported, though lead resistance may introduce error.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1737\" data-end=\"1835\"\u003e\n\u003cp data-start=\"1739\" data-end=\"1835\"\u003e\u003cstrong data-start=\"1739\" data-end=\"1755\"\u003e3-wire RTDs:\u003c\/strong\u003e Common in industrial use; compensates for lead resistance in balanced wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1836\" data-end=\"1930\"\u003e\n\u003cp data-start=\"1838\" data-end=\"1930\"\u003e\u003cstrong data-start=\"1838\" data-end=\"1854\"\u003e4-wire RTDs:\u003c\/strong\u003e Recommended for highest accuracy; eliminates lead resistance effects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1932\" data-end=\"2051\"\u003eAny platinum RTD probe with a Temperature Coefficient of Resistance (TCR) of 0.00385 can be used with the SRP-10.\u003c\/p\u003e","published_at":"2020-12-18T20:42:00-08:00","created_at":"2020-12-18T20:42:00-08:00","vendor":"ACR Systems","type":"","tags":["SmartReader Plus Family"],"price":126200,"price_min":126200,"price_max":126200,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37804123979947,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"01-0132","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"SmartReader Plus 10 - Three-Channel RTD Temperature Logger","public_title":null,"options":["Default Title"],"price":126200,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2358_400_300.jpg?v=1610170794","\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2362_400_300.jpg?v=1610170816","\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2365_400_300.jpg?v=1610170839"],"featured_image":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2358_400_300.jpg?v=1610170794","options":["Title"],"media":[{"alt":null,"id":15547901247659,"position":1,"preview_image":{"aspect_ratio":1.267,"height":300,"width":380,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2358_400_300.jpg?v=1610170794"},"aspect_ratio":1.267,"height":300,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2358_400_300.jpg?v=1610170794","width":380},{"alt":null,"id":15547901673643,"position":2,"preview_image":{"aspect_ratio":3.053,"height":131,"width":400,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2362_400_300.jpg?v=1610170816"},"aspect_ratio":3.053,"height":131,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2362_400_300.jpg?v=1610170816","width":400},{"alt":null,"id":15547902623915,"position":3,"preview_image":{"aspect_ratio":1.384,"height":289,"width":400,"src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2365_400_300.jpg?v=1610170839"},"aspect_ratio":1.384,"height":289,"media_type":"image","src":"\/\/www.acrdatasolutions.com\/cdn\/shop\/products\/2365_400_300.jpg?v=1610170839","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp data-start=\"1259\" data-end=\"1632\"\u003eThe SmartReader Plus 10 (SRP-10) is a proven RTD data logger built for research, QA, and temperature-critical industrial applications. With four total channels — three external RTD inputs and one internal thermistor channel — the SRP-10 delivers the accuracy, flexibility, and ruggedness required in industries where reliable temperature monitoring is non-negotiable.\u003c\/p\u003e\n\u003ch3 data-start=\"1634\" data-end=\"1660\"\u003eSupported RTD Types\u003c\/h3\u003e\n\u003cul data-start=\"1661\" data-end=\"1930\"\u003e\n\u003cli data-start=\"1661\" data-end=\"1736\"\u003e\n\u003cp data-start=\"1663\" data-end=\"1736\"\u003e\u003cstrong data-start=\"1663\" data-end=\"1679\"\u003e2-wire RTDs:\u003c\/strong\u003e Supported, though lead resistance may introduce error.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1737\" data-end=\"1835\"\u003e\n\u003cp data-start=\"1739\" data-end=\"1835\"\u003e\u003cstrong data-start=\"1739\" data-end=\"1755\"\u003e3-wire RTDs:\u003c\/strong\u003e Common in industrial use; compensates for lead resistance in balanced wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1836\" data-end=\"1930\"\u003e\n\u003cp data-start=\"1838\" data-end=\"1930\"\u003e\u003cstrong data-start=\"1838\" data-end=\"1854\"\u003e4-wire RTDs:\u003c\/strong\u003e Recommended for highest accuracy; eliminates lead resistance effects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1932\" data-end=\"2051\"\u003eAny platinum RTD probe with a Temperature Coefficient of Resistance (TCR) of 0.00385 can be used with the SRP-10.\u003c\/p\u003e"}